Soil Testing (NATA Accreditation under process)
- AS1289.1.1 Preparation of disturbed soil samples for testing
- AS1289.1.2.1 Sampling and preparation of soils—Disturbed samples—Standard method
- AS1289.1.4.1 Selection of sampling or test sites—Random number method
- AS1289.1.4.2 Selection of sampling or test sites—Stratified random number method
- AS1289.2.1.1 Determination of the moisture content of a soil—Oven drying method (standard method)
- AS1289.3.1.1 Determination of the liquid limit of a soil—Four point Casagrande method
- AS1289.3.1.2 Determination of the liquid limit of a soil—One point Casagrande method (subsidiary method)
- AS1289.3.2.1 Determination of the plastic limit of a soil—Standard method
- AS1289.3.3.1 Calculation of the plasticity index of a soil
- AS1289.3.3.2 Calculation of the cone plasticity index of a soil
- AS1289.3.4.1 Determination of the linear shrinkage of a soil—Standard method
- AS1289.3.6.1 Determination of the particle size distribution of a soil—Standard method of analysis
- AS1289.3.8.1 Determination of Emerson class number of a soil
- AS1289.3.8.2 Dispersion—Determination of the percent dispersion of a soil
- As1289.3.8.3 Determination of the pinhole dispersion classification of a soil
- AS1289.3.9.1 Determination of the cone liquid limit of soil
- AS1289.3.9.2 Determination of the cone liquid limit of soil—One point method
- AS1289.4.3.1 Determination of the pH value of a soil —Electrometric method
- AS1289.4.4.1 Determination of the electrical resistivity of a soil—Method for sands and granular materials
- AS1289.5.1.1 Determination of the dry density/moisture content relation of a soil using standard compactive effort
- AS1289.5.2.1 Determination of the dry density/moisture content relation of a soil using modified compactive effort
- AS1289.5.3.1 Sand replacement method using a sand-cone pouring apparatus
- AS1289.5.4.1 Dry density ratio, moisture variation and moisture ratio
- AS1289.5.4.2 Assignment of maximum dry density ratio and optimum moisture content values
- AS1289.5.4.3 Compaction control test—Dry density ratio and moisture ratio using statistical selection of reference values
- AS1289.5.7.1 Compaction control test—Hilf density ratio and Hilf moisture variation (rapid method)
- AS1289.5.8.1 Determination of field density and field moisture content of a soil using a nuclear surface moisture-density gauge—Direct transmission mode
- AS1289.6.1.1 Determination of the California Bearing Ratio of a soil—Standard laboratory method for a remoulded specimen
- AS1289.6.3.2 Determination of the penetration resistance of a soil—9 kg dynamic cone penetrometer test
- AS1289.6.3.3 Determination of the penetration resistance of a soil with a Perth sand penetrometer test
- AS1289.6.7.1 Determination of the permeability of a soil—Constant head method for a remoulded specimen
- AS1289.6.7.2 Determination of the permeability of a soil—Falling head method for a remoulded specimen
- AS1289.7.1.1 Determination of the shrinkage index of a soil—Shrink-swell index
- AS1141.12 & 1141.33 Material finer than 75 microns and clay and Silt content